ASTM E213 DOWNLOAD

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. This standard is issued under the fixed designation E ; the number immediately 1 This practice is under the jurisdiction of ASTM Committee E07 on Nonde-. 1 Jun ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing.

Author: Gurn Nezuru
Country: Ethiopia
Language: English (Spanish)
Genre: Relationship
Published (Last): 15 October 2013
Pages: 254
PDF File Size: 17.70 Mb
ePub File Size: 11.13 Mb
ISBN: 856-6-77981-906-6
Downloads: 90281
Price: Free* [*Free Regsitration Required]
Uploader: JoJogor

This standard does not purport to address all of the safety concerns, if any, associated with its use.

Because before I got a question from a client about the grade of the reference standard used is different from the grade of material being tested The conclusion astm e213 the sound velocity for both materials are the same or in other words that the mechanical properties do not always change the acoustical properties, do you agree? So for every pipe or tube of same grade you have to make calibration block with the same grade astm e213 the same lot.

In short no transfer loss. astm e213

astm e213 Active view current version of standard. The procedure inAnnexA2 may be used to determine the helical scan pitch. Certain combinations of search unit size, astm e213, thin wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce erroneous test results. If you have any change in mechanical properties there will be a change in acoustic property.

The reference pipe or tube shall be astm e213 of discontinuities or other conditions producing indications that r213 interfere with detection of the reference notches. Artificial discontinuities consisting of longitudinal reference notches are employed as the astm e213 means of calibrating the aetm system. These procedures have been successful with smaller sizes.

Referenced Documents purchase separately The documents listed below are astm e213 within the subject standard but are not provided as part of the standard.

TOP Related Posts  HICKOK 600A PDF

ASTM E – 98 Standard Practice for Ultrasonic Examination of Metal Pipe and Tubing NO_PDF

These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full volume coverage of pipes and tubes, including those with low ratios of outside diameter-to-wall thickness, and to avoid astm e213 signal astm e213 when examining small-diameter, thin-wall tubes.

Stainless Steel Tubing and Pipe: The values stated in inch-pound units are to be regarded as standard. Gokul, Thanks for your reply, from your description then I do the testing of the 2 materials astm e213 different mechanical properties API 5CT grade material, L and P carbon steel.

The SI equivalents are in parentheses astm e213 may be approximate. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The astm e213 in Annex A2 may be used to determine the helical scan pitch. These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full volume coverage of pipes and tubes, including those with low ratios of outside diameter to wall thicknessand to avoid spurious signal responses astm e213 examining small-diameter, thin-wall tubes.

ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Standard ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using ultrasonic methods. My question what is the meaning of “acoustical properties”? Link to Active This link will always route astm e213 the current Active version of the standard.

TOP Related Posts  ASKEP KEJANG DEMAM PADA ANAK PDF DOWNLOAD

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine astm e213 applicability of regulatory limitations prior to use. These procedures have been used successfully for smaller sizes, astm e213, and may be astm e213 upon contractural agreement between the using parties. The procedure in Annex A1 is applicable to pipe and tubing used in nuclear and other special and safety astm e213 tions.

Kusnadi, I believe you misunderstood. The SI equivalents are in parentheses and may astm e213 approximate. Do I need to make axial and circurmferential nothces and to scan 2 directions axial and 2 circumferential for best results? Historical F213 s – view previous versions of standard.

Kusnadi, Acoustical properties means how the sound behaves in a material. This practice covers a procedure for detecting astm e213 tinuities in metal pipe and steel tubing during a volumetric exami- nation using ultrasonic methods.

Specific techniques of the ultrasonic method to which this practice astm e213 include pulse-reflection techniques, both contact and non-contact for example, as described in Guide Eand angle beam immersion techniques. Link to Active Astm e213 link will always route to the current Active version of the standard. What I meant was even a small change in mechanical property, will result a change in acoustic property.

If transverse as well as longitudinal examination is desired, a procedure for employing transverse notches is provided. ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- astm e213 using ultrasonic methods.