ASTM E213 EBOOK DOWNLOAD

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. This standard is issued under the fixed designation E ; the number immediately 1 This practice is under the jurisdiction of ASTM Committee E07 on Nonde-. 1 Jun ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing.

Author: Voodoozil Mikaran
Country: Estonia
Language: English (Spanish)
Genre: Automotive
Published (Last): 23 October 2013
Pages: 324
PDF File Size: 3.28 Mb
ePub File Size: 6.56 Mb
ISBN: 524-8-77115-178-5
Downloads: 57543
Price: Free* [*Free Regsitration Required]
Uploader: Vomuro

This standard does not purport to address all of the safety concerns, if any, associated with its use. Astm e213 to Active This link will always route to the current Active version of the standard.

ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing

In short no transfer loss. Stainless Steel Astm e213 and Pipe: Standard ASTM E Standard for Ultrasonic Testing of Metal Pipe Astm e213 This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation astm e213 ultrasonic methods. The SI equivalents are in parentheses and may be approximate. The procedure in Annex A2 may be used to determine ashm helical scan pitch. Specific techniques of the ultrasonic method to which this practice applies include pulse-reflection techniques, both contact and non-contact for example, as described in Guide Eand angle beam immersion axtm.

Certain combinations of search unit size, frequency, thin wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce astm e213 test results. These procedures are intended to ensure that proper beam angles and beam axtm are used to provide full volume coverage of pipes and tubes, astm e213 those with low ratios of outside diameter to wall thicknessand to avoid spurious signal responses astm e213 examining small-diameter, thin-wall tubes.

If transverse as well as longitudinal examination is desired, a procedure for employing transverse notches is provided. If you have any change in mechanical astm e213 there will be a change in acoustic property. Nickel Alloy Seamless Tubes: The values stated in inch-pound astm e213 are to be regarded w213 standard.

TOP Related Posts  RH436 EPUB

Artificial discontinuities consisting of longitudinal reference notches are employed as the primary means of calibrating the ultrasonic system. The reference pipe or tube shall be free of discontinuities or other conditions producing indications that can interfere with detection of the reference notches. Referenced Documents purchase separately Astm e213 documents astm e213 below are referenced within the subject standard but are not provided as part of the astm e213.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine atm applicability of regulatory limitations prior to use. These procedures have been used successfully for smaller sizes, however, and may be specified upon contractural agreement between the using parties.

Referenced Documents purchase separately The documents listed astm e213 are referenced within e13 subject standard but astm e213 not provided as part of the standard. Kusnadi, Acoustical properties means how astm e213 sound behaves in a material. What I meant was even a small change in mechanical property, will result a change in acoustic property. The SI equivalents are in parentheses and may be approximate.

Link to Active This link will always route to the current Active version of the standard.

The procedure inAnnexA2 may be used to determine the astm e213 scan pitch. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full volume coverage of pipes and tubes, including those with low ratios of outside diameter-to-wall thickness, and to avoid asfm signal responses when examining small-diameter, thin-wall tubes.

Historical Version s – view previous versions of standard. Astn SI equivalents are in parentheses astm e213 may be approximate. My question what is the meaning of astm e213 properties”? Artificial reflectors consisting of longitudinal, and, when specified by the using party or parties, transverse reference notches placed on the surfaces of a reference standard are employed as the primary means of standardizing the ultrasonic system.

TOP Related Posts  DELL 2007FP EBOOK DOWNLOAD

ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice covers a procedure for detecting discon- tinuities in metal e23 and steel tubing during a volumetric exami- astm e213 using ultrasonic methods. In a set of two constant material at constant atmospheric pressure and temperature, sound behaves exactly the same.

Kusnadi, I believe you misunderstood. Astm e213 view current version of standard. Gokul, Thanks for your reply, e2133 your description then I do the testing e2133 the 2 materials have different mechanical properties API 5CT grade material, L and Astm e213 carbon steel. The procedure in Annex A1 is applicable to pipe and tubing e2213 in nuclear and other special and safety applica- tions. This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during astm e213 volumetric exami- nation using ultrasonic methods.

Astm e213 before I got a question from a client about the grade of the reference standard used is different from the grade of material aastm tested The conclusion that the sound velocity for both materials are the same or s213 other words that the mechanical properties do not astm e213 change the acoustical properties, do you agree?

Do I need to make axial and circurmferential nothces and to scan 2 directions axial and 2 circumferential for best results? So for every pipe or tube of same grade you have to make calibration block with the same grade from astm e213 same lot.

It is the responsibility of the user of this standard to establish appropriate safety and 2e13 astm e213 and determine the applicability of regulatory limitations prior to use. These procedures have been successful with smaller sizes. These may be specified astm e213 contractual agreement between the using parties.

These procedures have been successful with smaller sizes.